0

Out of 0 Ratings

Owner's of the Axis Communications Security Camera 215 PTZ gave it a score of 0 out of 5. Here's how the scores stacked up:
  • Reliability

    0 out of 5
  • Durability

    0 out of 5
  • Maintenance

    0 out of 5
  • Performance

    0 out of 5
  • Ease of Use

    0 out of 5
of 53
 
AXIS 215 PTZ/AXIS 215 PTZ-E - Setup
19
Show Setup link
Note that unchecking the box for Show set
up link will remove the setup link from the
camera’s Home Page. The setup tools will then only be accessible by entering the full setup
address into the address/URL field of a browser, i.e.
Own Home Page
To use a previously uploaded web page as the default page, check the
checkbox, select the page from the drop-down list and click OK.
Note:
You can also add live video from the AXIS 215 PTZ/AXIS 215 PTZ-E to your own web site.
For further information, please refer to HTML Examples, on page 20.
User Defined Links
Enter a descriptive name and enter the URL in the provided field. The link
will appear on the Live View page.
User defined CGI links can be used to issue
The VAPIX® API requests, e.g.
PTZ commands.
Example:
1. Check Show
custom link 1
2. Enter a descriptive name, e.g. CAM START.
3. Select the Use as cgi link radio button and enter the cgi link in the field:
4. Check Show
custom link 2.
5. Enter a descriptive name, e.g. CAM STOP.
6. Select the Use as cgi link radio button and enter the cgi link in the field:
7. These links will appear in the web interface and can be used to control the PTZ camera.
For more information on the The VAPIX® API, see the Support
/ Developer pages on the Axis Website at
http://www.axis.com
Action Buttons -
these buttons can then be used to manually trigger and stop an event from the Live View page.
See Event Servers, on page
23.
The snapshot button allows users to take
a snapshot of the video stream and save it on a computer.
Output Buttons (AXIS 215 PTZ only) - th
ese buttons can then be used to manually start and stop an event from
the Live View page, e.g. switch a light on/off:
The Pulse button activates the port for a defined period
Active/Inactive displays 2 buttons, one for each action
(on/off)
Default Video Format - select
default video format from the drop-down list. Check the box to enable video
format selection from the Live View Page.
Default Viewer
http://<ip address>/operator/basic.shtml
http://192.168.0.125/axis-cgi/com/ptz.cgi?continuouspantiltmove=-30,-30
http://192.168.0.125/axis-cgi/com/ptz.cgi?continuouspantiltmove=0,0
user defined link